Choose the type of following :
 
 
 
 
 
    Product Range » EPCOS
    Silent Features »
    PhaseCap AC Capacitors
    PhaseCap HD AC Capacitors
    WindCap AC Capacitors
    For Wind Turbine
    PhiCap AC Capacitors
    SquareCap AC Capacitors
    Standards & Technical Data »
    PhaseCap AC Capacitors
    PhaseCap HD AC Capacitors
    WindCap AC Capacitors
    For Wind Turbine
    PhiCap AC Capacitors
    SquareCap AC Capacitors
    Dimensions & Drawings »
    PhaseCap AC Capacitors
    PhaseCap HD AC Capacitors
    WindCap AC Capacitors
    For Wind Turbine
    PhiCap AC Capacitors
    SquareCap AC Capacitors
    Dimensional & Drawings »
    PhaseCap AC Capacitors
    PhaseCap HD AC Capacitors
    WindCap AC Capacitors
    For Wind Turbine
    PhiCap AC Capacitors
 
 
   

[EPCOS POWER FACTOR CORRECTION]

PHASECAP ® AC CAPACITORS - [TECHNICAL DATA]    

 

Standards IEC 831-1/96, IEC 831-2/95, EN 60831-1 +2/96, VDE 560-46+47 3/95.
 
     
Overvoltage U max. Un + 10 % (Up to 8 h daily) /Un + 15 % (Up to 30
    min daily) / Un + 30 % (up to 1 min)
Overcurrent I max. 1.3 * In, in certain cases higher [See Table]
Inrush current Is 200 * In
Losses (Dieelectric)   < 0.25 W/kvar
Capacitence tolernace   + 5%
Test voltage, terminal / terminal UTT 2.15 * Un1, AC, 10 s
Test voltage, terminal / case UTC up to Un > 660 V:300 Vac, 10 s;above Un = 660V:
    6000 Vac, 10 s.
Useful life Tld (co) 115,000 h
Ambient temperature LCT/ -40% D max. 55° C, with forced cooling higher
  UCT ambient temperature possible: in some cases differ
    ent temperature category for 60 Hz (see table).
Cooling   natural or forced.
Humidity Hrel max. 95%
Altitude   4000 m above sea level.
Mounting Position   random.
Mounting and Grounding   threaded M 12 stud on bottom of case
Safety   dry technology, overpressure disconnector, self
    healing
Discharge resistors   discharge module included
Case   extruded aluminium
Enclosure   IP20, indoor mounting (optionally with lid for IP54)
Dielectric   Polypropylene film
Impregnation   non-PCB, inert gas
Terminals   dual, three-way SIGUT terminal strip with eletric
    shock protection (VDE 0106 part 100), max.16 mm²
    cable cross-section
Certification   cUL file #E966954.
     
 
PHASECAP ® AC CAPACITORS - [TECHNICAL DATA]    
  The compact PhaseCap capacitor is a self-healing, metalized polypropylene film capacitor. The
  current carrying metal layer (electrode) is vapor-deposited onto one side of the film.
   
   
PHASECAP ® AC CAPACITORS - [ COMPACT DESIGN - LOW HEIGHT WEIGHT AND VOLUME ]    
  Compact design - low height, weight and volume : Three electrically separated, partial
  capacitors are wound concentrically in a single operation onto an insulated metal core tube,
  which guarantees excellent winding precision. The electrodes are connected by metal spraying
  the face end of the winding element. The partial capacitors are star; delta or series connected.
  The compact MKK winding elements are housed in a cylindrical aluminum case and
  hermetically sealed by a press-rolled metal lid.
   
PHASECAP ® AC CAPACITORS - [ TRIPLE SAFETY SYSTEM ]    
  Dry technology : instead of a liquid impregnating agent the capacitor is filled with gas. So
  there is no risk of fire caused by spurting or leaking oil. Dry design is a must for ecologically
  sensitive applications and insurance follow-up.
  Self-healing: the capacitor repairs itself after overload.
  Overpressure disconnector : this prevents the capacitor from bursting at the end of its useful
  life or through electrical or thermal overload.
   
   
PHASECAP ® AC CAPACITORS - [INNOVATIVE AND RELIABLE SIGUT ® CONNECTION TECHNOLOGY ]    
  SIGUT terminals ensure reliable and straight forward connection, even in a parallel capacitor
  circuit with benefits like
  Simplified parallel connection of input ends in series.
  Protection against electric shock hazard (IP20/IP54/ to VDE 0106 part 100),
  additional connection of discharge resistors for extra reliability and safety,
  clamping device to prevent loosening of screws,
  cable cross-sections up to 16mm².
   
   
PHASECAP ® AC CAPACITORS - [EXTENDED USEFUL LIFE OF 115,000 OPERATING HOURS]    
  After a long drying phase in a high vacuum to eliminate moisture from the active element, the
  capacitor is impregnated. The case is filled with inert gas and sealed. Then routine test are
  performed for gas leakage.
  This production process helps to avoid oxidation and partial discharges (corona effect),
  promoting capacitance stability over an extremely long period, an essential in filter circuit
  applications.
   
   
PHASECAP ® AC CAPACITORS - [EXTENDED USEFUL LIFE OF 115,000 OPERATING HOURS]    
  Capacitors used for power factor correction undergo a lot of switching operations. The high
  inrush currents that go along with this must be handled without degrading useful life. The pulse
  strength of this technology comes in particular from the enlarged, sensitive contact area
  (improved metal spraying). The breakthrough came with a Siemens patent called the wavy
  cut, plus heavy edge film design. PhaseCap capacitors can easily handle inrush currents of up
  to 200 times rated current.
   
   
PHASECAP ® AC CAPACITORS - [AND WHERE IT IS CRUCIAL]    
  Parallel connection of capacitors.
  Non-detuned capacitors.
  Capacitor banks using standard contactors.
  Restoration after voltage interruptions and brownouts.
   
   
PHASECAP ® AC CAPACITORS - [OVERPRESSURE DISCONNECTOR]    
 
Overpressure Disconnector
 
 * LP- List Price inclusive of excise duty but exclusive of sales tax or any other taxes.
  For Improved power quality and reduction in energy costs. Top  
Regd.Office : 13/D Yusuf Building, Gr. Floor, 72 Mangaldas Road, Lohar Chawl, Mumbai - 400002, Maharashtra, India.
* Tel. : +91 [022] 22010546 / 22092690 / 22066260 / 22067151 * Telefax : +91 [022] 22197440 / 22056141.
* Email.: response@paraginternational.com / paragin@yahoo.com.* Website : http://www.paraginternational.com
   Created & Hosted By - MID Promoted By - GID